ANALYTICAL
REQUIREMENTS FOR ARKANSAS GENERAL PERMITS
|
|
| |
| Coal
Mining and Coal Exploration - ARG040000 |
|
| 100 |
Controlled Surface Mine Drainage |
|
| 200 |
Non-Controlled
Surface Mine Drainage |
|
| |
Iron,
Total
Manganese, Total
Total Suspended Solids
pH
|
EPA
200.7, 200.8
EPA 200.7, 200.8
EPA 160.2
EPA 150.1 |
| 201 |
Alternate Limits for Non-controlled Surface Mine Drainage for Precipitation
Events |
| 202 |
Alternate Limits - Any discharge or increase in volume of discharge
caused by Precipitation Event |
| |
Iron
Settleable Solids
pH
|
EPA
200.7, 200.8
EPA 160.5
EPA 150.1 |
| 300 |
Post-Mining
Areas |
|
|
Settleable
Solids
pH
|
EPA
160.5
EPA 150.1 |
| 400 |
Alternate
Limits for Precipitation Greater Than 10-Year, 24-Hour Storm Event |
|
| |
pH
|
EPA
150.1 |
| 500 |
Instream
Monitoring Stations |
|
|
Total
Dissolved Solids
Sulfates
|
EPA
160.1
EPA 300.0 |
| |
|
|
| Sanitary
Landfills - ARG160000 |
|
|
COD
Total Suspended Solids
Oil and Grease
pH
|
HACH
8000
EPA 160.2
EPA 1664
EPA 150.1 |
| |
|
| Self-Service
Laundry - ARG190000 |
|
|
Coliform,
Fecal
COD
Total Suspended Solids
Oil and Grease
pH
|
SM 9222
HACH 8000
EPA 160.2
EPA 1664
EPA 150.1 |
| |
|
| Petroleum
Storage - ARG340000 |
|
| 101 |
Discharges from secondary containment areas (dikes) surrounding petroleum
storage tanks |
| 201 |
A
Discharges from petroleum loading and transfer areas |
|
Oil
and Grease
pH
|
EPA
1664
EPA 150.1 |
| 201B |
Discharges from petroleum loading and transfer areas and tank bottom
water |
|
Oil
and Grease
Total BTEX
Total Dissolved Solids
Ammonia
Benzene
Total Cyanide
Lead, Total
Napthalene
Acute Static Renewal 48 Hour - Fathead Minnow
pH
|
EPA
1664
EPA 624
EPA 160.1
SM 4500-NH3N-B,E
EPA 624
EPA 335.2
EPA 200.7, 200.8
EPA 624
EPA 600/4-90/027
EPA 150.1 |
| 301 |
Petroleum
tank truck washings |
|
|
Oil
and Grease
COD
Total Suspended Solids
pH
|
EPA
1664
HACH 8000
EPA 160.2
EPA 150.1 |
| 401 |
Discharges from petroleum tank truck garages located adjacent to petroleum
storage and transfer areas |
| 601 |
Contaminated stormwater runoff covered by or commingled with above
stated discharges |
|
Oil
and Grease
pH
|
EPA
1664
EPA 150.1 |
| |
|
| Individual
Treatment - ARG550000 |
|
| |
BOD
Coliform, Fecal
Total Suspended Solids
pH
|
EPA
405.1
SM 9222
EPA 160.2
EPA 150.1 |
| |
|
| Water
Treatment - ARG640000 |
|
| 101 |
Discharge
from WTP with alum or other aluminum compounds in coagulants |
| |
Total
Suspended Solids
Iron, Dissolved
Manganese, Dissolved
Aluminum, Dissolved
pH
|
EPA
160.2
EPA 200.7, 200.8
EPA 200.7, 200.8
EPA 200.7, 200.8
EPA 150.1 |
| 102 |
Discharge
from WTP not using alum or other aluminum compounds in coagulants |
| |
Total
Suspended Solids
Iron, Dissolved
Manganese, Dissolved
pH
|
EPA
160.2
EPA 200.7, 200.8
EPA 200.7, 200.8
EPA 150.1 |
| |
|
| Hydrostatic
Testing - ARG670000 |
|
| |
Total
Suspended Solids
Oil and Grease
Total Organic Carbon
Benzene
BTEX, Total
pH
|
EPA
160.2
EPA 1664
EPA 415.1
EPA 624
EPA 624
EPA 150.1 |
| |
|
|
| Car/Truck
Wash - ARG750000 |
|
| |
COD
Total Suspended Solids
Oil and Grease
Copper
Nickel
Lead
Zinc
|
HACH
8000
EPA 160.2
EPA 1664
EPA 200.7, 200.8
EPA 200.7, 200.8
EPA 200.7, 200.8
EPA 200.7, 200.8 |
| |
|
|
| Groundwater
Cleanup - ARG790000 |
|
| |
Total
Petroleum Hydrocarbons
Benzene
BTEX, Total
Acute Static Renewal 48 Hour - Fathead Minnow
|
EPA
1664
EPA 624
EPA 624
EPA 600/4-90/027 |